Skip to content
First set of IIO fixes for the 4.4 cycle.

This set does not include those for issues introduced during the merge
window.  Fixes of those will follow in a future series.

* ad5064
  - Make sure the local i2c_write returns 0 on success rather than the
    number of bytes transfered.  Otherwise we report an error on all writes.
  - Fix a shift for ad5629 and ad5669 which gives incorrect DAC output on
    these parts.
* ad7793
  - The product ID on the datasheet is wrong.  Fix it in the driver.
* IIO_DUMMY_EVGEN
  - select IRQ_WORK as a dependency.
* lpc32xx
  - make sure clock is prepared before enabling.
* si7020
  - data byte order was reversed. Fix it.
* vf610
  - Internal temperature calculation was wrong if a different
    reference voltage was used.  Now use a linear interpolation
    function to make it work over the full range.
  - Fix a division by zero in the case of a device tree property
    not being present (same issue two fixes).
* xilinx XADC
  - VREFN scale was wrong - fix it.